Introducing the DO9100 Waterproof Oxygen Concentration Meter 0.0-40.0 Mg/L, an epitome of precision and reliability in the realm of dissolved oxygen and temperature measurement. Equipped with a state-of-the-art microcomputer processor, this device masterfully computes and compensates for measurement data, guaranteeing unmatched precision. Enclosed within an IP67-rated durable and waterproof shell, it promises unwavering performance across varied environments. The DO9100 caters to diverse requirements with dual measurement units: % and mg/L. Its revolutionary probe, featuring an advanced polarographic sensor and thermistor, assures precise temperature measurement and compensation. The permeable film operates as a selective barrier, facilitating oxygen reaction measurement with stellar accuracy, while isolating the solution from the sensing electrode.
Measuring Range: Oxygen concentration (mg/L): 0.0-40.0 mg/L; Dissolved oxygen saturation (%): 0.0-300.0%; Temperature: 0-40°C (32-104°F). Resolution: Oxygen concentration (mg/L): 0.1 mg/L; Dissolved oxygen saturation (%): 0.1%; Temperature: 0.1°C (0.1°F). Accuracy: Oxygen concentration (mg/L): ±1.5% F.S.; Dissolved oxygen saturation (%): ±1.5% F.S.; Temperature: ±0.5°C. Calibration Mode: Accommodates single-point or dual-point automatic calibration, incorporating zero point or automatic 100% calibration in air. Response Time: ≤45s (swift response at 20°C). Temperature Compensation: ATC (0-50°C). Battery Power: Low-battery warning notification. Height Compensation: None. Shut Down: Automatic shut down after approximately 15 minutes. Power Supply Mode: 3*1.5V button batteries (not included). Use Environment: 0-40°C (32-104°F); RH max 90%. Dimensions and Weight: 183*37*37mm (7.2*1.5*1.5in)/80g.
Measuring range |
Oxygen concentration (mg/L) |
0.0-40. 0 mg/L |
Dissolved oxygen saturation (%) |
0.0-300. 0% |
|
Temperature |
0-40°C; 32-104°F |
|
Resolution |
Oxygen concentration (mg/L) |
0.1 mg/L |
Dissolved oxygen saturation (%) |
0.1% |
|
Temperature |
0, 1°C; 0.1°F |
|
Accuracy |
Oxygen concentration (mg/L) |
±1.5% °F. S. |
Dissolved oxygen saturation (%) |
±1.5%F. S. |
|
Temperature |
±0.5 |
|
Calibration mode |
support single-point or dual-point automatic calibration, namely zero point or automatic 100% calibration in the air |
Response time |
≤45s (fast response at 20) |
Temperature Compensation |
ATC (0-50) |
Battery power |
low battery warning |
Height compensation |
none |
Shut down |
automatically shut down for about 15 minutes |
Power supply mode |
3*1. 5V button battery (not included) |
Use environment |
0-40 (32-104°F);RH max 90% |
Dimensions and weight |
183*37*37mm (7.2*1.5*1.5in)/80g |
Package List: 1 x Host, 1 x Dissolved Oxygen Electrode, 3 x Dissolved Oxygen Membrane Groups, 1 x Manual. Each element is meticulously packaged to ensure safe transit and pristine delivery.
Installation Instructions
Calibration: Select either one-point or two-point calibration for optimal precision. For standard applications, one-point calibration suffices: 0.0% (oxygen-free water) or 100.0% (air). For enhanced accuracy, choose two-point calibration: Execute both 0.0% (oxygen-free water) and 100.0% (air) calibrations sequentially. The calibration process is intuitive-ensure the probe is correctly installed before starting. 1. 100.0% - Once the device is activated and value stabilization occurs in the air, begin calibration. Press and hold the CAL button for 5 seconds, then release. The screen will flash 100.0%, signaling successful calibration. 2. 0.0% - Similarly, in anaerobic water with the device powered on, calibrate by pressing and holding the CAL button for 5 seconds, then release. The screen will flash 0.0% to confirm successful calibration.
Henan Bingsheng Industrial Co., Ltd., a prominent leader with 2 years of expertise in the industry, is celebrated for its steadfast dedication to quality, fostering customer trust and satisfaction.
Q: Are you manufacturers?
A: Yes, we are a manufacturing company with 10 years of factory experience.
Q: Do you support customization?
A: We support OEM and ODM customization.
Q: What is your shipping time and delivery cycle?
A: We guarantee 7-day shipping and 14 day receiving.
Q: How can we ensure quality?
A: Before mass production, it is always a sample before production;
Always conduct final inspection before shipment.
Q: What is your minimum order quantity?
A: Our minimum order quantity is 1 piece.